Mastervolt Sunmaster 130S
Two networks of 32 inverters each can be connected to one PIB-IV board.
 |
ON/OFF |
 |
I solar |
 |
U solar |
 |
I mains |
 |
U mains |
 |
Temperature |
 |
E total |
|
 |
Mastervolt Sunmaster 1800
Two networks of 32 inverters each can be connected to one PIB-IV board.
 |
GND Error |
 |
AtoD Error |
 |
ON/OFF |
 |
I solar |
 |
U solar |
 |
I mains |
 |
U mains |
 |
Fan duty-cycle |
 |
E total |
|
 |
Mastervolt Sunmaster 2500
Two networks of 32 inverters each can be connected to one PIB-IV board.
 |
I solar |
 |
U solar |
 |
I mains |
 |
U mains |
 |
P mains |
 |
F mains |
 |
E mains |
 |
E mains (reactive) |
 |
E total |
 |
Temperature |
 |
Error flags |
 |
Isolation failure |
 |
External alarm |
 |
Externally switched off |
 |
U grid too low |
 |
U grid too high |
 |
F grid too low |
 |
F grid too high |
 |
T too high |
 |
ON/OFF |
 |
Address (lo byte) |
 |
Address (hi byte) |
|
 |
Siemens Inverter
Two inverters can be connected to one PIB-IV board.
 |
U mains (rms) |
 |
I mains (rms) |
 |
P mains |
 |
U solar |
 |
I solar |
 |
P solar |
 |
T heatsink |
 |
E total |
 |
E yesterday |
 |
E last month |
 |
Error bits |
 |
Efficiency |
 |
I too high alarm |
 |
T too high |
 |
U too low |
 |
U too high |
 |
U mains alarm |
 |
Hardware control alarm |
 |
Internal supply alarm |
 |
ON/OFF |
 |
Version number |
|
 |
OK4 AC module
Two networks of 32 inverters each can be connected to one PIB-IV board.
 |
E total |
 |
Iac (counts) |
 |
Uac (counts) |
 |
Udc (counts) |
 |
Tinv (counts) |
 |
Tinv (Celsius) |
 |
WhCAL |
 |
UacCAL |
 |
UdcSTOP |
 |
UdcSTART |
|
 |
ASP module
Two inverters can be connected to a single PIB-IV board.
 |
Udc |
 |
Idc |
 |
Umains |
 |
Pmains |
 |
Etoday |
 |
Etotal |
|
 |
SMA Sunny Boy SWR 700
Two networks of 32 inverters each can be connected to one PIB-IV board.
 |
Sample command |
 |
Age of sampled values |
 |
U mains |
 |
I mains |
 |
P mains |
 |
F mains |
 |
U solar |
 |
I solar |
 |
E total |
 |
Op. hours |
 |
Serial # |
 |
Mains Connections |
 |
Fault Count |
 |
R-Iso |
 |
Zac |
|
 |
ABB F2 M-bus Heat Meter
A network of 64 meters max. can be connected to a single PIB-IV board. An
additional M-bus power supply and converter is required (included in the
delivery when ordered as M-bus interface).
 |
Energy total |
 |
Volume total |
 |
Temp. hot side |
 |
Temp. cold side |
 |
Actual power |
 |
Actual flow |
 |
Pulse count |
 |
Network address |
 |
Age of meter data |
|
 |
Senertec combined power and heat generator
Two Senertecs can be connected to a single PIB-IV board.
 |
Operation hours |
 |
Temperature hot side |
 |
Temperature cold side |
 |
Total electrical energy |
 |
Total heat |
 |
Actual electric power |
 |
Age of latest info |
|
 |
Viterra M-bus Heat Meter
A network of 64 meters max. can be connected to a single PIB-IV board. An
additional M-bus power supply and converter is required (included in the
delivery when ordered as M-bus interface).
 |
Energy total |
 |
Volume total |
 |
Temp. hot side |
 |
Temp. cold side |
 |
Actual power |
 |
Actual flow |
 |
Pulse count |
 |
Network address |
 |
Age of meter data |
|